ElettroLaser MS 3.5 & MS 165 Troubleshooting -Romanoff

<--View Previous Screen


Trouble Shotting- Elletro Laser Jewelry Engraver

The following table lists a series of potential issues which may take place (due to incorrect use / operations with MS 3.5
and/or due to machinery faults).

  • Inadequate processing quality (and consequently insufficient quality of the product);
  • Inadequate efficiency / productivity levels;
  • Hazards for the machine and/or operator.

The table lists the possible cause and solution(s) to be implemented for each issue. If the problem cannot be solved with the solutions proposed below, please contact the Elettrolaser Customer Service: please refer to chapter 12 for details on how to request support.

# Issue Solution(s)
1 The machine turns on but does not reach the START position.
  • Check the position of the safety key.
2 The display shows the settings, but the laser fails to shoot.
  • Check the connection between the machine and the control pedal
3 The shutter closes the visual path in the microscope and turns dark, but there is no effect on the welded workpiece.
  • The power and time settings are too low;
  • Laser source out of alignment;
  • The positioning glass is dirty (please refer to paragraph
    9.2.4).
4 The lights in the welding chamber fail to turn on.
  • Check the position of the activation switch and of the
    calibration switch for the lights inside the welding
    chamber;
  • Check the fuses.
5 When using the laser, the smoke generated by the welding
floats upwards, towards the microscope, and clouds the
operator’s view
  • The filter on the internal fan of the welding chamber is
    too dirty;
  • If the fan is not operating, check the fuse.
6 No shield gas is released when pressing the control pedal.
  • Check on the display that the gas release countdown is
    activated
  • Check that the input pressure level does not exceed 2
    bar;
  • Check the gas flow calibration by using the regulator
    inside the welding chamber
  • Check that no foreign object is blocking the passage of
    gas in the rear connection.
7 The laser fails to turn on.
  1. Check that the power switch of the machine is set on the “I” position;
  2. Check that the emergency press-button is not pressed;
  3. Check the fuses;
  4. Check the connection to the electrical power network.